| Model |
SPRINSTERS S I |
SPRINSTERS S II |
SPRINSTERS S III |
SPRINSTERS S IV |
SPRINSTERS S V |
SPRINSTERS S VI |
| Light Source |
LUMILEDS / TYF |
LUMILEDS / TYF |
LUMILEDS / TYF |
LUMILEDS / TYF |
LUMILEDS / TYF |
LUMILEDS / TYF |
| LED Series |
5050 |
5050 |
5050 |
5050 |
5050 |
5050 |
| Power |
80W |
100W |
120W |
150W |
180W |
200W |
| Luminous Flux (absolute) |
14,600Lm |
16,900Lm |
20,300Lm |
25,400Lm |
29,900Lm |
33,200Lm |
| Luminaire Efficacy |
>160Lm/W (Verified) |
>160Lm/W (Verified) |
>160Lm/W (Verified) |
>160Lm/W (Verified) |
>160Lm/W (Verified) |
>160Lm/W (Verified) |
| Colour Temperature (CCT) |
3500K |
3500K |
3500K |
3500K |
3500K |
3500K |
| Colour Rendering Index (CRI) |
75±5 |
75±5 |
75±5 |
75±5 |
75±5 |
75±5 |
| LED Life Span |
50,000 |
50,000 |
50,000 |
50,000 |
50,000 |
50,000 |
| Lumen Maintenance @ 50,000 Hours |
70% Lumen Maintenance |
70% Lumen Maintenance |
70% Lumen Maintenance |
70% Lumen Maintenance |
70% Lumen Maintenance |
70% Lumen Maintenance |
| Housing Design |
Block Module Type |
Block Module Type |
Block Module Type |
Block Module Type |
Block Module Type |
Block Module Type |
| Housing Material |
Die-Cast Aluminium Alloy |
Die-Cast Aluminium Alloy |
Die-Cast Aluminium Alloy |
Die-Cast Aluminium Alloy |
Die-Cast Aluminium Alloy |
Die-Cast Aluminium Alloy |
| Operating Temperature Range |
-40°C ~ +50°C |
-40°C ~ +50°C |
-40°C ~ +50°C |
-40°C ~ +50°C |
-40°C ~ +50°C |
-40°C ~ +50°C |
| Working Humidity Range |
10~90% RH |
10~90% RH |
10~90% RH |
10~90% RH |
10~90% RH |
10~90% RH |
| Driver |
External |
External |
External |
External |
External |
External |
| Operating Voltage |
220-240Vac |
220-240Vac |
220-240Vac |
220-240Vac |
220-240Vac |
220-240Vac |
| Classification |
Class I |
Class I |
Class I |
Class I |
Class I |
Class I |
| Power Factor |
>0.95 |
>0.95 |
>0.95 |
>0.95 |
>0.95 |
>0.95 |
| SPD (Surge Protective Device) |
External 25kA |
External 25kA |
External 25kA |
External 25kA |
External 25kA |
External 25kA |
| Glass Cover Material |
Tempered Glass |
Tempered Glass |
Tempered Glass |
Tempered Glass |
Tempered Glass |
Tempered Glass |
| Dimming Control Output |
0-10V/PWM/DALI (Optional) |
| NEMA Socket |
Support NEMA, ZigBee Smart Lighting System (Optional) |
| Ingress Protection For Luminaire |
IP66 |
IP66 |
IP66 |
IP66 |
IP66 |
IP66 |
| Installation DIameter (MM) |
''Horizontal Installation
57~63MM'' |
''Horizontal Installation
57~63MM'' |
''Horizontal Installation
57~63MM'' |
''Horizontal Installation
57~63MM'' |
''Horizontal Installation
57~63MM'' |
''Horizontal Installation
57~63MM'' |
| Torque Mounting |
15 N-m |
15 N-m |
15 N-m |
15 N-m |
15 N-m |
15 N-m |
| Installation Height |
8-10 Meters |
8-10 Meters |
8-10 Meters |
10-12 Meters |
10-12 Meters |
10-12 Meters |
| Maintenance |
''Non-User Replaceable Light Source “The light source contained in this luminaire shall only be replaceable by manufacturer or his service agent or a similarqualified person”, Top Open Cover Access And Tool-Free Clip Lock At Gear Compartment |
| Fixture Dimension, N.W |
613x240x109mm, 4.8Kg |
613x240x109mm, 4.8Kg |
613x240x109mm, 4.8Kg |
683x260x109mm, 5.7Kg |
683x260x109mm, 5.7Kg |
693x300x109mm, 6.3Kg |
| Compliance LM80 (LED Chip) |
|
|
|
|
|
|
| Compliance LM79 (Luminaire) |
|
|
|
|
|
|
| Maintenance |
EN 61347-1, EN 61347-2-13, EN 55015/GB 17743, EN61000-3-2/GB 17625.1, EN 61000-3-3, EN 61000-4-2,-3,-4,-5,-6,-8,-11, EN 61547 |
| Maintenance |
IEC 62722-1, IEC 62722-2-1, IEC 60598-1, IEC 60598-2-3, IEC 62471, IEC 62493, IEC 62031, IES LM79-08 |